| Assessment Year | 1982 |
|---|---|
| Principal Product | SOLENOIDS & SWITCHES |
| NAICS |
n/a
|
| SIC | 3679: Electronic Components, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 340 |
| Plant Area |
n/a
|
| Annual Production | 600,000
pieces
|
| Production Hrs. Annual | 0
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $138,673 | 2,891,266 |
kWh
|
$0.048 |
| Natural Gas | $14,635 | 4,357 |
MMBtu
|
$3.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7245: Use direct air supply to exhaust hoods | $2,701 | $624 | - |
$2,701
-
MMBtu
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $281 | $500 |
$281
5,862
kWh
|
- | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,458 | - |
$1,458
-
kWh
|
- | |
| TOTAL RECOMMENDED | $4,440 | $1,124 |
$1,739
5,862
kWh
|
$2,701
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs