Assessment Year | 1981 |
---|---|
Principal Product | CAULKS,SEALANTS,ETC. |
NAICS |
n/a
|
SIC | 2891: Adhesives and Sealants |
Sales Range | $10 M to 50M |
# of Employees | 158 |
Plant Area |
n/a
|
Annual Production | 37,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,625 | 2,175,557 |
kWh
|
$0.042 |
Natural Gas | $45,494 | 15,841 |
MMBtu
|
$2.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,769 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,769 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $123 | $300 |
$123
2,931
kWh
|
- | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $1,251 | $752 |
$1,251
29,601
kWh
|
- | |
03 | 2.2515: Use optimum thickness insulation | $245 | - |
$60
1,465
kWh
|
$185
-
MMBtu
|
|
04 | 2.5196: Use small number of high output units instead of many small inefficient units | $2,698 | $760 | - |
$2,698
-
MMBtu
|
|
05 | 2.7494: Install storm windows and doors | $1,452 | $1,208 | - |
$1,452
-
MMBtu
|
|
TOTAL RECOMMENDED | $5,769 | $3,020 |
$1,434
33,997
kWh
|
$4,335
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,769 | $3,020 |
$1,434
33,997
kWh
|
$4,335
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs