| Assessment Year | 2026 |
|---|---|
| Principal Product | Aerospace |
| NAICS | 336411: Aircraft Manufacturing |
| SIC | 3812: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical Systems and Instruments |
| Sales Range | $10 M to 50M |
| # of Employees | 72 |
| Plant Area |
50,000
ft2
|
| Annual Production | 100,000
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | New Hampshire |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $368,661 | 2,928,636 |
kWh
|
$0.13 |
| Electricity Demand | $118,140 | 5,352 |
kW-mo/yr
|
$22.07 |
| Electricity Fees | $2,906 | - |
|
- |
| LPG | $12,990 | 499 |
MMBtu
|
$26.03 |
| TOTAL YEARLY COSTS | $502,696 | |||
| RECOMMENDED SAVINGS* | $18,335 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,873 | $715 |
$1,579
12,544
kWh
|
$294
-
kW-mo/yr
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,592 | - |
$5,109
40,579
kWh
|
$1,483
-
kW-mo/yr
|
- | |
| 03 | 2.7314: Reduce ventilation air | $1,410 | $6,600 |
$854
6,781
kWh
|
$556
-
kW-mo/yr
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,558 | $1,500 |
$4,105
32,624
kWh
|
$1,002
-
kW-mo/yr
|
$2,451
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $902 | $2,450 |
$772
6,132
kWh
|
$130
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $18,335 | $11,265 |
$12,419
98,660
kWh
|
$3,465
-
kW-mo/yr
|
$2,451
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs