Assessment Year | 2024 |
---|---|
Principal Product | Sheet metal |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
60,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $55,609 | 617,560 |
kWh
|
$0.090 | |
Electricity Demand | $36,994 | 2,430 |
kW-mo/yr
|
$15.23 | |
Electricity Fees | $6,422 | - |
|
- | |
Natural Gas | $28,346 | 2,505 |
MMBtu
|
$11.32 | |
Waste Disposal Costs | |||||
Water Usage | $2,427 | 276 |
Tgal
|
$8.79 | |
TOTAL YEARLY COSTS | $129,798 | ||||
RECOMMENDED SAVINGS* | $29,603 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $680 | - | - | - | $680 | - | |
02 | 2.8123: Pay utility bills on time | $247 | - | - | - | $247 | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $6,358 | - | - | - | $6,358 | - | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $2,533 | $75 |
$2,533
28,115
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,630 | $1,300 |
$1,139
12,638
kWh
|
$491
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $511 | $225 |
$357
3,962
kWh
|
$154
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $1,217 | $900 |
$1,120
12,432
kWh
|
$97
-
kW-mo/yr
|
- | - | |
08 | 2.9114: Use solar heat to make electricty | $16,427 | $124,645 |
$19,062
211,560
kWh
|
- | - | $(-2,635.0) | |
TOTAL RECOMMENDED | $29,603 | $127,145 |
$24,211
268,707
kWh
|
$742
-
kW-mo/yr
|
$7,285 | $(-2,635.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs