| Assessment Year | 2024 |
|---|---|
| Principal Product | Specialty gas cylinders |
| NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
| SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 110 |
| Plant Area |
76,000
ft2
|
| Annual Production | 100,000
units
|
| Production Hrs. Annual | 3,250
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $506,033 | 5,665,800 |
kWh
|
$0.089 |
| Electricity Demand | $211,723 | 11,239 |
kW-mo/yr
|
$18.84 |
| Electricity Fees | $131,064 | - |
|
- |
| Natural Gas | $422,661 | 28,074 |
MMBtu
|
$15.06 |
| Other Gas | $252,882 | 1,916 |
MMBtu
|
$132.01 |
| TOTAL YEARLY COSTS | $1,524,363 | |||
| RECOMMENDED SAVINGS* | $183,498 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,770 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $2,850 | - | - | - | $2,850 | - | |
| 02 | 2.8123: Pay utility bills on time | $208 | - | - | - | $208 | - | |
| 03 | 2.2136: Install / repair insulation on steam lines | $123 | $139 | - | - | - |
$123
-
MMBtu
|
|
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $1,157 | $100 |
$1,157
12,956
kWh
|
- | - | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $504 | $75 |
$392
4,356
kWh
|
$112
-
kW-mo/yr
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $588 | $1,300 |
$456
5,110
kWh
|
$132
-
kW-mo/yr
|
- | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,041 | $5,000 |
$3,135
35,109
kWh
|
$906
-
kW-mo/yr
|
- | - | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $115,385 | $54,067 |
$115,385
1,292,100
kWh
|
- | - | - | |
| 09 | 2.9114: Use solar heat to make electricty | $58,641 | $633,762 |
$58,641
656,678
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $183,498 | $694,443 |
$179,166
2,006,308
kWh
|
$1,150
-
kW-mo/yr
|
$3,058 |
$123
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,770 | $1,439 |
$456
5,110
kWh
|
$132
-
kW-mo/yr
|
$3,058 |
$123
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs