ITAC Assessment: UC2402
ITAC logo
ITAC Assessment: UC2402
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Rubber product
NAICS 326299: All Other Rubber Product Manufacturing
SIC 3069: Fabricated Rubber Products, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 25
Plant Area 21,000
ft2
Annual Production 20,000,000
lb
Production Hrs. Annual 2,500
hrs
Location (State) Connecticut

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $57,540 481,601
kWh
Electricity Demand $53,548 2,217
kW-mo/yr
Electricity Fees $9,262 -
Natural Gas $31,271 2,820
MMBtu
TOTAL YEARLY COSTS $151,620
RECOMMENDED SAVINGS* $45,065 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.9114: Use solar heat to make electricty $17,049 $134,289 $17,049
142,666
kWh
- - -
02 2.3141: Use battery storage for demand control $7,849 $31,027 $(-610.8)
(-5,111)
kWh
$8,694
-
kW-mo/yr
- $(-234.5)
03 2.2136: Install / repair insulation on steam lines $1,298 $3,327 - - $1,298
-
MMBtu
-
04 2.4239: Eliminate or reduce compressed air usage $2,943 $1,040 $2,363
19,778
kWh
$579
-
kW-mo/yr
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $2,261 $150 $1,770
14,809
kWh
$491
-
kW-mo/yr
- -
06 2.6231: Utilize controls to operate equipment only when needed $4,612 $30 $4,612
38,593
kWh
- - -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $419 $1,300 $328
2,744
kWh
$91
-
kW-mo/yr
- -
08 2.6231: Utilize controls to operate equipment only when needed $1,934 $155 $1,934
16,187
kWh
- - -
09 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $6,701 $64,088 $13,928
116,550
kWh
$4,999
-
kW-mo/yr
$(-12,225.7)
-
MMBtu
-
TOTAL RECOMMENDED $45,065 $235,406 $41,373
346,216
kWh
$14,854
-
kW-mo/yr
$(-10,928.2)
-
MMBtu
$(-234.5)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs