ITAC Assessment: UC2301
ITAC logo
ITAC Assessment: UC2301
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Cleaning wiping products
NAICS 322299: All Other Converted Paper Product Manufacturing
SIC 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 36
Plant Area 138,000
ft2
Annual Production 500,000
thousand feet
Production Hrs. Annual 2,000
hrs
Location (State) Connecticut

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $37,244 718,840
kWh
Electricity Demand $43,409 3,089
kW-mo/yr
Electricity Fees $4,362 -
Natural Gas $34,927 2,776
MMBtu
TOTAL YEARLY COSTS $119,942
RECOMMENDED SAVINGS* $45,612 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
01 2.3192: Use fossil fuel powered generator during peak demand periods $19,647 - $476
9,180
kWh
$2,867
-
kW-mo/yr
$20,400 - $(-4,095.9) -
02 2.4231: Reduce the pressure of compressed air to the minimum required $520 $600 $240
4,641
kWh
$280
-
kW-mo/yr
- - - -
03 2.6231: Utilize controls to operate equipment only when needed $407 $600 $407
7,852
kWh
- - - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $552 $2,800 $255
4,924
kWh
$297
-
kW-mo/yr
- - - -
05 2.1321: Replace fossil fuel equipment with electrical equipment $669 $3,250 $(-200.6)
(-3,873)
kWh
$(-558.2)
-
kW-mo/yr
- $1,178
-
MMBtu
- $250
06 2.7229: Air condition only space necessary $1,959 $1,200 - - - $1,959
-
MMBtu
- -
07 2.9114: Use solar heat to make electricty $21,858 $127,920 $24,417
219,780
kWh
- - - $(-2,559.0) -
TOTAL RECOMMENDED $45,612 $136,370 $25,595
242,504
kWh
$2,886
-
kW-mo/yr
$20,400 $3,136
-
MMBtu
$(-6,654.9) $250
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs