ITAC Assessment: UC2207
ITAC logo
ITAC Assessment: UC2207
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Metal casting
NAICS 331524: Aluminum Foundries (except Die-Casting)
SIC 3365: Aluminum Foundries
Sales Range $10
M
to 50
M
# of Employees 55
Plant Area 51,000
ft2
Annual Production 10,000
units
Production Hrs. Annual 2,000
hrs
Location (State) Connecticut

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,401 744,960
kWh
Electricity Demand $60,592 4,021
kW-mo/yr
Electricity Fees $5,267 -
Natural Gas $7,063 402
MMBtu
Fuel Oil #2 $13,647 522
MMBtu
TOTAL YEARLY COSTS $164,970
RECOMMENDED SAVINGS* $97,263 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Fuel Oil #2 Savings Personnel Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $378 $464 $193
1,834
kWh
$166
-
kW-mo/yr
- - $19
02 2.4231: Reduce the pressure of compressed air to the minimum required $2,727 $500 $1,893
17,990
kWh
$834
-
kW-mo/yr
- - -
03 2.6231: Utilize controls to operate equipment only when needed $12,731 $500 $12,731
120,957
kWh
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,359 $2,800 $3,359
31,933
kWh
- - - -
05 2.6218: Turn off equipment when not in use $2,876 $500 $2,876
27,331
kWh
- - - -
06 2.1332: Convert combustion equipment to burn natural gas $4,478 $3,300 - - $(-9,169.3)
-
MMBtu
$13,647
-
MMBtu
-
07 2.9114: Use solar heat to make electricty $70,713 $379,682 $59,314
563,821
kWh
$18,988
-
kW-mo/yr
- - $(-7,589.0)
TOTAL RECOMMENDED $97,263 $387,746 $80,367
763,866
kWh
$19,988
-
kW-mo/yr
$(-9,169.3)
-
MMBtu
$13,647
-
MMBtu
$(-7,569.8)
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Fuel Oil #2 Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs