Assessment Year | 2012 |
---|---|
Principal Product | Aluminum Ingots |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | greater than $500 M |
# of Employees | 900 |
Plant Area |
4,356,000
ft2
|
Annual Production | 831,225,988
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $12,971,789 | 393,954,353 |
kWh
|
$0.033 |
Electricity Demand | $11,321,826 | 759,527 |
kW-mo/yr
|
$14.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $162,826 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $54,140 | $50 |
$33,385
1,013,820
kWh
|
$20,755
-
kW-mo/yr
|
|
02 | 2.6231: Utilize controls to operate equipment only when needed | $31,511 | $15,063 |
$19,419
589,698
kWh
|
$12,092
-
kW-mo/yr
|
|
03 | 2.6218: Turn off equipment when not in use | $12,180 | $50 |
$7,528
228,620
kWh
|
$4,652
-
kW-mo/yr
|
|
04 | 2.4323: Use optimum size and capacity equipment | $64,995 | $90,750 |
$40,125
1,218,500
kWh
|
$24,870
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $162,826 | $105,913 |
$100,457
3,050,638
kWh
|
$62,369
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs