| Assessment Year | 2010 |
|---|---|
| Principal Product | Finished Pipe |
| NAICS | 238320: Painting and Wall Covering Contractors |
| SIC | 1721: Painting and Paper Hanging |
| Sales Range | $5 M to 10M |
| # of Employees | 21 |
| Plant Area |
65,600
ft2
|
| Annual Production | 35,000
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $199,068 | 1,762,640 |
kWh
|
$0.11 |
| Electricity Fees | $23,911 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,958 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,695 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,330 | $5,324 |
$2,330
20,639
kWh
|
|
| 02 | 2.7134: Use photocell controls | $197 | $112 |
$197
1,742
kWh
|
|
| 03 | 2.7261: Install timers and/or thermostats | $773 | $170 |
$773
6,845
kWh
|
|
| 04 | 2.7261: Install timers and/or thermostats | $316 | $50 |
$316
2,797
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,276 | $800 |
$5,276
46,728
kWh
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,472 | $5,000 |
$4,472
39,615
kWh
|
|
| 07 | 2.4239: Eliminate or reduce compressed air usage | $1,594 | $1,550 |
$1,594
14,118
kWh
|
|
| TOTAL RECOMMENDED | $14,958 | $13,006 |
$14,958
132,484
kWh
|
||
| TOTAL IMPLEMENTED | $8,695 | $6,344 |
$8,695
77,009
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs