Assessment Year 2010
Principal Product Finished Pipe
NAICS 238320: Painting and Wall Covering Contractors
SIC 1721: Painting and Paper Hanging
Sales Range $5
M
to 10
M
# of Employees 21
Plant Area 65,600
ft2
Annual Production 35,000
pieces
Production Hrs. Annual 2,210
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $199,068 1,762,640
kWh
Electricity Fees $23,911 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,958 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,695

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,330 $5,324 $2,330
20,639
kWh
02 2.7134: Use photocell controls $197 $112 $197
1,742
kWh
03 2.7261: Install timers and/or thermostats $773 $170 $773
6,845
kWh
04 2.7261: Install timers and/or thermostats $316 $50 $316
2,797
kWh
05 2.4231: Reduce the pressure of compressed air to the minimum required $5,276 $800 $5,276
46,728
kWh
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,472 $5,000 $4,472
39,615
kWh
07 2.4239: Eliminate or reduce compressed air usage $1,594 $1,550 $1,594
14,118
kWh
TOTAL RECOMMENDED $14,958 $13,006 $14,958
132,484
kWh
TOTAL IMPLEMENTED $8,695 $6,344 $8,695
77,009
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings