Assessment Year | 2010 |
---|---|
Principal Product | car seats |
NAICS | 336360: Motor Vehicle Seating and Interior Trim Manufacturing |
SIC | 2531: Public Building and Related Furniture |
Sales Range | $100 M to 500M |
# of Employees | 482 |
Plant Area |
360,000
ft2
|
Annual Production | 103,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $497,770 | 7,662,500 |
kWh
|
$0.065 |
Electricity Demand | $114,695 | 21,314 |
kW-mo/yr
|
$5.38 |
Electricity Fees | $66,932 | - |
|
- |
Natural Gas | $66,021 | 44,537 |
MMBtu
|
$1.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $124,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $86,882 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $42,535 | $960 |
$18,785
289,000
kWh
|
- |
$23,750
-
MMBtu
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $22,945 | $37,030 |
$21,865
336,400
kWh
|
$1,080
-
kW-mo/yr
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $6,600 | $10,620 |
$6,600
101,520
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,740 | $7,420 |
$18,740
263,635
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,382 | $640 |
$5,382
82,851
kWh
|
- | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $7,833 | $10,000 |
$7,297
112,234
kWh
|
$536
-
kW-mo/yr
|
- | |
07 | 2.7442: Keep doors and windows shut when not on use | $12,114 | - |
$1,429
21,997
kWh
|
- |
$10,685
-
MMBtu
|
|
08 | 2.7442: Keep doors and windows shut when not on use | $970 | $2,880 |
$970
14,930
kWh
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,313 | $15,697 |
$5,452
83,931
kWh
|
$861
-
kW-mo/yr
|
- | |
10 | 2.6218: Turn off equipment when not in use | $828 | - |
$828
12,752
kWh
|
- | - | |
TOTAL RECOMMENDED | $124,260 | $85,247 |
$87,348
1,319,250
kWh
|
$2,477
-
kW-mo/yr
|
$34,435
-
MMBtu
|
||
TOTAL IMPLEMENTED | $86,882 | $27,597 |
$51,586
769,096
kWh
|
$861
-
kW-mo/yr
|
$34,435
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs