| Assessment Year | 2026 |
|---|---|
| Principal Product | Automotive Glasses |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $100 M to 500M |
| # of Employees | 145 |
| Plant Area |
120,000
ft2
|
| Annual Production | 2,370,704
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $377,845 | 4,078,181 |
kWh
|
$0.093 |
| Electricity Fees | $36,487 | - |
|
- |
| Natural Gas | $4,862 | 342 |
MMBtu
|
$14.22 |
| TOTAL YEARLY COSTS | $419,194 | |||
| RECOMMENDED SAVINGS* | $172,527 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $9,809 | $1,000 |
$8,945
96,498
kWh
|
$864 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,128 | $6,591 |
$1,029
11,102
kWh
|
$99 | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $71,801 | $230,861 |
$65,476
706,325
kWh
|
$6,325 | |
| 04 | 2.7261: Install timers and/or thermostats | $13,733 | $1,216 |
$12,523
135,079
kWh
|
$1,210 | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $1,361 | $541 |
$1,241
13,388
kWh
|
$120 | |
| 06 | 2.7135: Install occupancy sensors | $1,998 | $4,339 |
$1,822
19,656
kWh
|
$176 | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $164 | $231 |
$150
1,620
kWh
|
$14 | |
| 08 | 2.9114: Use solar heat to make electricty | $71,695 | $919,800 |
$65,379
705,270
kWh
|
$6,316 | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $838 | $1,931 |
$764
8,241
kWh
|
$74 | |
| TOTAL RECOMMENDED | $172,527 | $1,166,510 |
$157,329
1,697,179
kWh
|
$15,198 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs