| Assessment Year | 2026 |
|---|---|
| Principal Product | Vacuum Truck Parts |
| NAICS | 339999: All Other Miscellaneous Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
75,000
ft2
|
| Annual Production | 28
units
|
| Production Hrs. Annual | 3,000
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $109,000 | 634,630 |
kWh
|
$0.17 |
| Electricity Demand | $15,457 | 3,261 |
kW-mo/yr
|
$4.74 |
| Natural Gas | $17,521 | 1,252 |
MMBtu
|
$13.99 |
| TOTAL YEARLY COSTS | $141,978 | |||
| RECOMMENDED SAVINGS* | $82,922 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,050 | $800 |
$2,651
15,428
kWh
|
$337
-
kW-mo/yr
|
$62 | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,137 | $3,858 |
$2,841
16,535
kWh
|
$232
-
kW-mo/yr
|
$64 | - | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $7,231 | $15,914 |
$6,282
36,568
kWh
|
$801
-
kW-mo/yr
|
$148 | - | |
| 04 | 2.7442: Keep doors and windows shut when not on use | $7,420 | $736 | - | - | - |
$7,420
-
MMBtu
|
|
| 05 | 2.7135: Install occupancy sensors | $827 | $1,112 |
$810
4,717
kWh
|
- | $17 | - | |
| 06 | 2.9114: Use solar heat to make electricty | $60,992 | $448,560 |
$59,343
345,419
kWh
|
$400
-
kW-mo/yr
|
$1,249 | - | |
| 07 | 4.821: Pay bills on time to avoid late fees | $265 | - | - | - | $265 | - | |
| TOTAL RECOMMENDED | $82,922 | $470,980 |
$71,927
418,667
kWh
|
$1,770
-
kW-mo/yr
|
$1,805 |
$7,420
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs