Assessment Year | 2025 |
---|---|
Principal Product | Steel materials |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 50 |
Plant Area |
132,000
ft2
|
Annual Production | 84,000
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,467 | 650,960 |
kWh
|
$0.085 |
Electricity Demand | $50,274 | 2,530 |
kW-mo/yr
|
$19.87 |
Electricity Fees | $7,166 | - |
|
- |
Natural Gas | $11,730 | 1,701 |
MMBtu
|
$6.90 |
TOTAL YEARLY COSTS | $124,637 | |||
RECOMMENDED SAVINGS* | $71,113 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $232 | $250 |
$74
872
kWh
|
$143
-
kW-mo/yr
|
$15 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $813 | $1,572 |
$379
4,446
kWh
|
$382
-
kW-mo/yr
|
$52 | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $916 | $1,133 |
$580
6,809
kWh
|
$278
-
kW-mo/yr
|
$58 | |
04 | 2.7261: Install timers and/or thermostats | $5,323 | $29 |
$4,985
58,511
kWh
|
- | $338 | |
05 | 2.7135: Install occupancy sensors | $2,012 | $2,261 |
$1,884
22,118
kWh
|
- | $128 | |
06 | 2.9114: Use solar heat to make electricty | $46,922 | $377,678 |
$42,703
501,213
kWh
|
$1,240
-
kW-mo/yr
|
$2,979 | |
07 | 2.3212: Optimize plant power factor | $14,895 | $2,777 | - | - | $14,895 | |
TOTAL RECOMMENDED | $71,113 | $385,700 |
$50,605
593,969
kWh
|
$2,043
-
kW-mo/yr
|
$18,465 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs