Assessment Year | 2024 |
---|---|
Principal Product | Valve repair |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3491: Industrial Valves |
Sales Range | $50 M to 100M |
# of Employees | 187 |
Plant Area |
105,000
ft2
|
Annual Production | 8,000
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,220 | 895,520 |
kWh
|
$0.11 |
Electricity Fees | $19,321 | - |
|
- |
Natural Gas | $16,318 | 641 |
MMBtu
|
$25.46 |
TOTAL YEARLY COSTS | $133,859 | |||
RECOMMENDED SAVINGS* | $20,472 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,690 | $13,427 |
$7,262
66,198
kWh
|
$1,428 | - | |
02 | 2.7261: Install timers and/or thermostats | $6,430 | $1,437 |
$5,373
48,976
kWh
|
$1,057 | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $2,801 | $783 | - | - |
$2,801
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,762 | $8,114 |
$1,472
13,421
kWh
|
$290 | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $479 | $500 |
$400
3,645
kWh
|
$79 | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $310 | $88 |
$259
2,363
kWh
|
$51 | - | |
TOTAL RECOMMENDED | $20,472 | $24,349 |
$14,766
134,603
kWh
|
$2,905 |
$2,801
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs