Assessment Year | 2008 |
---|---|
Principal Product | Fabricated Metal Buildings |
NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
SIC | 3448: Prefabricated Metal Buildings and Components |
Sales Range | $50 M to 100M |
# of Employees | 239 |
Plant Area |
210,000
ft2
|
Annual Production | 39,518
ton
|
Production Hrs. Annual | 5,928
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $337,710 | 4,718,174 |
kWh
|
$0.072 |
Electricity Demand | $72,579 | 11,354 |
kW-mo/yr
|
$6.39 |
Electricity Fees | $17,056 | - |
|
- |
Natural Gas | $99,932 | 11,106 |
MMBtu
|
$9.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $130,655 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $117,270 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $100,400 | $59,650 |
$86,300
1,166,000
kWh
|
$14,100
-
kW-mo/yr
|
- | - | |
02 | 2.3212: Optimize plant power factor | $12,300 | $17,275 | - |
$12,300
-
kW-mo/yr
|
- | - | |
03 | 2.7145: Install skylights | $8,620 | $17,170 |
$7,990
108,050
kWh
|
$1,530
-
kW-mo/yr
|
- | $(-900.0) | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,000 | $350 |
$4,300
58,175
kWh
|
$700
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,000 | - |
$1,720
23,250
kWh
|
$280
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,085 | $620 |
$225
3,050
kWh
|
$25
-
kW-mo/yr
|
$835 | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $620 | - |
$620
8,365
kWh
|
- | - | - | |
08 | 2.4314: Use synthetic lubricant | $365 | - |
$310
4,216
kWh
|
$55
-
kW-mo/yr
|
- | - | |
09 | 2.7124: Make a practice of turning off lights when not needed | $265 | - |
$190
2,620
kWh
|
$75
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $130,655 | $95,065 |
$101,655
1,373,726
kWh
|
$29,065
-
kW-mo/yr
|
$835 | $(-900.0) | ||
TOTAL IMPLEMENTED | $117,270 | $77,170 |
$101,430
1,370,676
kWh
|
$16,740
-
kW-mo/yr
|
- | $(-900.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |