| Assessment Year | 2022 |
|---|---|
| Principal Product | Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $100 M to 500M |
| # of Employees | 140 |
| Plant Area |
1,000,000
ft2
|
| Annual Production | 180,000
units
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,091,053 | 35,474,616 |
kWh
|
$0.059 | |
| Electricity Demand | $404,250 | 76,993 |
kW-mo/yr
|
$5.25 | |
| Electricity Fees | $84,701 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $32,195 | 6,504 |
Tgal
|
$4.95 | |
| TOTAL YEARLY COSTS | $2,612,199 | ||||
| RECOMMENDED SAVINGS* | $651,742 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $142,667 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Water Usage Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $474,477 | $2,321,152 |
$428,211
7,264,206
kWh
|
$14,516 |
$31,750
-
Tgal
|
|
| 02 | 2.3212: Optimize plant power factor | $75,936 | $24,406 | - | $75,936 | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $47,564 | $3,635 |
$46,004
780,454
kWh
|
$1,560 | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $19,283 | $500 |
$18,651
316,408
kWh
|
$632 | - | |
| 05 | 2.8114: Change rate schedules or other changes in utility service | $15,315 | $800 | - | $15,315 | - | |
| 06 | 2.7261: Install timers and/or thermostats | $12,543 | $6,630 |
$12,132
205,828
kWh
|
$411 | - | |
| 07 | 2.7135: Install occupancy sensors | $3,323 | $3,005 |
$3,214
54,533
kWh
|
$109 | - | |
| 08 | 2.7134: Use photocell controls | $1,182 | $2,240 |
$1,143
19,388
kWh
|
$39 | - | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,119 | $5,072 |
$2,050
34,793
kWh
|
$69 | - | |
| TOTAL RECOMMENDED | $651,742 | $2,367,440 |
$511,405
8,675,610
kWh
|
$108,587 |
$31,750
-
Tgal
|
||
| TOTAL IMPLEMENTED | $142,667 | $44,988 |
$64,543
1,094,996
kWh
|
$78,124 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Water Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs