| Assessment Year | 1990 |
|---|---|
| Principal Product | STREET LIGHTING STANDARDS |
| NAICS |
n/a
|
| SIC | 3648: Lighting Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 107 |
| Plant Area |
n/a
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $87,946 | 1,438,453 |
kWh
|
$0.061 |
| Natural Gas | $37,212 | 10,755 |
MMBtu
|
$3.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,168 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,291 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,920 | $4,700 | - |
$1,920
-
MMBtu
|
|
| 02 | 2.6232: Install set-back timers | $1,130 | - |
$1,130
21,102
kWh
|
- | |
| 03 | 2.4312: Improve lubrication practices | $561 | - |
$561
9,086
kWh
|
- | |
| 04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $524 | $1,092 | - |
$524
-
MMBtu
|
|
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $345 | - |
$345
7,327
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $308 | $1,118 |
$308
4,689
kWh
|
- | |
| 07 | 2.6218: Turn off equipment when not in use | $292 | - |
$292
6,155
kWh
|
- | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $43 | $65 |
$43
586
kWh
|
- | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $45 | $5 |
$45
586
kWh
|
- | |
| TOTAL RECOMMENDED | $5,168 | $6,980 |
$2,724
49,531
kWh
|
$2,444
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,291 | $1,118 |
$2,291
41,032
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs