Assessment Year | 2022 |
---|---|
Principal Product | Street Sweepers |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3713: Truck and Bus Bodies |
Sales Range | $50 M to 100M |
# of Employees | 180 |
Plant Area |
128,000
ft2
|
Annual Production | 450
units
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,047 | 1,422,576 |
kWh
|
$0.069 |
Electricity Demand | $55,754 | 3,726 |
kW-mo/yr
|
$14.96 |
Electricity Fees | $7,654 | - |
|
- |
Natural Gas | $75,917 | 9,607 |
MMBtu
|
$7.90 |
TOTAL YEARLY COSTS | $237,372 | |||
RECOMMENDED SAVINGS* | $16,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,691 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $10,422 | $17,285 | - | - | - |
$10,422
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $960 | $850 |
$914
13,267
kWh
|
- | $46 | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $4,186 | $500 |
$1,288
18,690
kWh
|
$754
-
kW-mo/yr
|
$2,144 | - | |
04 | 2.7135: Install occupancy sensors | $695 | $423 |
$662
9,610
kWh
|
- | $33 | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $123 | $231 |
$77
1,119
kWh
|
$43
-
kW-mo/yr
|
$3 | - | |
TOTAL RECOMMENDED | $16,386 | $19,289 |
$2,941
42,686
kWh
|
$797
-
kW-mo/yr
|
$2,226 |
$10,422
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,691 | $18,866 |
$2,279
33,076
kWh
|
$797
-
kW-mo/yr
|
$2,193 |
$10,422
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs