| Assessment Year | 2021 |
|---|---|
| Principal Product | automotive components |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $1 M to 5M |
| # of Employees | 150 |
| Plant Area |
420,000
ft2
|
| Annual Production | 2,000,000
units
|
| Production Hrs. Annual | 5,225
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $461,468 | 7,794,000 |
kWh
|
$0.059 |
| Electricity Demand | $93,735 | 11,937 |
kW-mo/yr
|
$7.85 |
| Electricity Fees | $47,945 | - |
|
- |
| Natural Gas | $4,733 | 381 |
MMBtu
|
$12.42 |
| TOTAL YEARLY COSTS | $607,881 | |||
| RECOMMENDED SAVINGS* | $72,464 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $52,277 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $6,816 | $22,649 |
$6,274
105,959
kWh
|
- | $542 | |
| 02 | 2.7134: Use photocell controls | $8,709 | $24,348 |
$8,016
135,377
kWh
|
- | $693 | |
| 03 | 2.3212: Optimize plant power factor | $45,219 | $10,941 | - | - | $45,219 | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,058 | $9,682 |
$5,498
92,850
kWh
|
$999
-
kW-mo/yr
|
$561 | |
| 05 | 2.7442: Keep doors and windows shut when not on use | $2,529 | $100 |
$2,328
39,297
kWh
|
- | $201 | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,133 | $4,930 |
$1,107
18,696
kWh
|
$856
-
kW-mo/yr
|
$170 | |
| TOTAL RECOMMENDED | $72,464 | $72,650 |
$23,223
392,179
kWh
|
$1,855
-
kW-mo/yr
|
$47,386 | ||
| TOTAL IMPLEMENTED | $52,277 | $20,623 |
$5,498
92,850
kWh
|
$999
-
kW-mo/yr
|
$45,780 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs