| Assessment Year | 2021 |
|---|---|
| Principal Product | non woven fabrics |
| NAICS | 314999: All Other Miscellaneous Textile Product Mills |
| SIC | 2297: Non-woven Fabrics |
| Sales Range | $10 M to 50M |
| # of Employees | 24 |
| Plant Area |
220,000
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 6,656
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $146,921 | 2,341,800 |
kWh
|
$0.063 |
| Electricity Demand | $142,901 | 9,234 |
kW-mo/yr
|
$15.48 |
| Electricity Fees | $11,593 | - |
|
- |
| TOTAL YEARLY COSTS | $301,415 | |||
| RECOMMENDED SAVINGS* | $9,537 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,537 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,051 | $4,640 |
$2,696
42,979
kWh
|
$1,199
-
kW-mo/yr
|
$156 | |
| 02 | 2.7135: Install occupancy sensors | $2,919 | $2,696 |
$2,807
44,738
kWh
|
- | $112 | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,152 | $3,309 |
$928
14,799
kWh
|
$1,141
-
kW-mo/yr
|
$83 | |
| 04 | 2.7261: Install timers and/or thermostats | $415 | $290 |
$399
6,367
kWh
|
- | $16 | |
| TOTAL RECOMMENDED | $9,537 | $10,935 |
$6,830
108,883
kWh
|
$2,340
-
kW-mo/yr
|
$367 | ||
| TOTAL IMPLEMENTED | $9,537 | $10,935 |
$6,830
108,883
kWh
|
$2,340
-
kW-mo/yr
|
$367 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs