Assessment Year 2020
Principal Product Joists and Decking for Metal Buildings
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3441: Fabricated Structural Metal
Sales Range $100
M
to 500
M
# of Employees 288
Plant Area 486,400
ft2
Annual Production 150,000
ton
Production Hrs. Annual 7,500
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $485,706 7,959,600
kWh
Electricity Demand $407,835 33,408
kW-mo/yr
Electricity Fees $(-102,624.0) -
Natural Gas $321,436 28,782
MMBtu
TOTAL YEARLY COSTS $1,112,353
RECOMMENDED SAVINGS* $117,945 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $6,594 $700 $2,728
44,703
kWh
- $(-313.0) $4,179
-
MMBtu
02 2.4231: Reduce the pressure of compressed air to the minimum required $4,693 $100 $3,018
49,452
kWh
$2,284
-
kW-mo/yr
$(-609.0) -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $21,587 $2,185 $16,977
278,213
kWh
$7,412
-
kW-mo/yr
$(-2,802.0) -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $84,652 $115,026 $63,384
1,038,744
kWh
$32,257
-
kW-mo/yr
$(-10,989.0) -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $419 $1,016 $259
4,251
kWh
$214
-
kW-mo/yr
$(-54.0) -
TOTAL RECOMMENDED $117,945 $119,027 $86,366
1,415,363
kWh
$42,167
-
kW-mo/yr
$(-14,767.0) $4,179
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs