ITAC Assessment: UA0181
ITAC logo
ITAC Assessment: UA0181
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Furniture
NAICS 337121: Upholstered Household Furniture Manufacturing
SIC 2512: Wood Household Furniture, Upholstered
Sales Range $50
M
to 100
M
# of Employees 407
Plant Area 650,000
ft2
Annual Production 440,000
units
Production Hrs. Annual 2,500
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $224,063 2,362,436
kWh
Electricity Demand $63,967 8,306
kW-mo/yr
Electricity Fees $7,384 -
TOTAL YEARLY COSTS $295,414
RECOMMENDED SAVINGS* $74,092 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,357

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $54,103 $88,547 $37,959
400,240
kWh
$14,794
-
kW-mo/yr
$1,350
02 2.7135: Install occupancy sensors $5,103 $11,746 $4,976
52,469
kWh
- $127
03 2.4231: Reduce the pressure of compressed air to the minimum required $5,742 $500 $4,213
44,418
kWh
$1,386
-
kW-mo/yr
$143
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,999 $2,465 $3,121
32,906
kWh
$778
-
kW-mo/yr
$100
05 2.7261: Install timers and/or thermostats $3,255 $1,850 $3,174
33,463
kWh
- $81
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,890 $987 $1,208
12,740
kWh
$651
-
kW-mo/yr
$31
TOTAL RECOMMENDED $74,092 $106,095 $54,651
576,236
kWh
$17,609
-
kW-mo/yr
$1,832
TOTAL IMPLEMENTED $12,357 $16,061 $11,271
118,838
kWh
$778
-
kW-mo/yr
$308
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs