Assessment Year | 1997 |
---|---|
Principal Product | Plastic Bottles |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 197 |
Plant Area |
84,100
ft2
|
Annual Production | 182,500,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $346,707 | 9,904,455 |
kWh
|
$0.035 |
Electricity Demand | $198,200 | 17,976 |
kW-mo/yr
|
$11.03 |
Electricity Fees | $7,474 | - |
|
- |
Natural Gas | $38,160 | 8,195 |
MMBtu
|
$4.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $77,961 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $77,961 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,784 | $4,207 |
$1,672
56,565
kWh
|
$1,112
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,346 | $12,020 |
$2,895
97,890
kWh
|
$2,451
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $36,864 | $37,700 |
$22,215
750,586
kWh
|
$14,649
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.1116: Improve combustion control capability | $13,512 | $22,440 |
$1,832
61,841
kWh
|
$1,280
-
kW-mo/yr
|
$10,400
-
MMBtu
|
- | - | - | - | |
05 | 3.7122: Maximize production runs to reduce cleaning | $16,379 | $1,440 | - | - | - |
$14,269
-
gal
|
- | $1,440 | $670 | |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,519 | - | - | - | - | - |
$2,519
-
lb
|
- | - | |
07 | 4.131: Modify process to reduce material use/cost | $557 | $1,500 | - | - | - | - | - | $557 | - | |
TOTAL RECOMMENDED | $77,961 | $79,307 |
$28,614
966,882
kWh
|
$19,492
-
kW-mo/yr
|
$10,400
-
MMBtu
|
$14,269
-
gal
|
$2,519
-
lb
|
$1,997 | $670 | ||
TOTAL IMPLEMENTED | $77,961 | $79,307 |
$28,614
966,882
kWh
|
$19,492
-
kW-mo/yr
|
$10,400
-
MMBtu
|
$14,269
-
gal
|
$2,519
-
lb
|
$1,997 | $670 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs