Assessment Year | 2015 |
---|---|
Principal Product | snack cakes |
NAICS | 311812: Commercial Bakeries |
SIC | 2041: Flour and Other Grain Mill Products |
Sales Range | $100 M to 500M |
# of Employees | 360 |
Plant Area |
280,000
ft2
|
Annual Production | 37,000
ton
|
Production Hrs. Annual | 6,624
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,085,546 | 14,950,156 |
kWh
|
$0.073 |
Electricity Fees | $238,622 | - |
|
- |
Natural Gas | $630,536 | 191,080 |
MMBtu
|
$3.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $254,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,532 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $94,692 | $86,201 |
$80,247
1,105,179
kWh
|
$14,445 | - | |
02 | 2.7135: Install occupancy sensors | $525 | $822 |
$445
6,130
kWh
|
$80 | - | |
03 | 2.7134: Use photocell controls | $328 | $61 |
$278
3,826
kWh
|
$50 | - | |
04 | 2.1113: Reduce combustion air flow to optimum | $20,453 | $39,438 | - | - |
$20,453
-
MMBtu
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $15,077 | $800 |
$12,777
175,964
kWh
|
$2,300 | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,679 | $2,995 |
$12,440
171,333
kWh
|
$2,239 | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,579 | $1,800 |
$4,728
65,119
kWh
|
$851 | - | |
08 | 2.7261: Install timers and/or thermostats | $3,588 | $80 |
$3,041
41,883
kWh
|
$547 | - | |
09 | 2.8121: Apply for tax-free status for energy purchases | $99,699 | $100 | - | $99,699 | - | |
TOTAL RECOMMENDED | $254,620 | $132,297 |
$113,956
1,569,434
kWh
|
$120,211 |
$20,453
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,532 | $3,878 |
$13,163
181,289
kWh
|
$2,369 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs