Assessment Year | 1999 |
---|---|
Principal Product | Electronic Circuits |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
155,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $542,665 | 16,597,597 |
kWh
|
$0.033 |
Electricity Demand | $270,102 | 51,150 |
kW-mo/yr
|
$5.28 |
Electricity Fees | $30,817 | - |
|
- |
Natural Gas | $117,257 | 31,694 |
MMBtu
|
$3.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,447 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7273: Install desiccant humidity control system | $26,618 | $64,698 |
$15,340
469,226
kWh
|
$11,278
-
kW-mo/yr
|
- | - | |
02 | 2.2113: Repair or replace steam traps | $10,071 | $450 | - | - |
$10,071
-
MMBtu
|
- | |
03 | 2.2628: Utilize a less expensive cooling method | $1,940 | $1,972 |
$1,940
59,203
kWh
|
- | - | - | |
04 | 3.4155: Meter waste water | $3,741 | $4,595 | - | - | - |
$3,741
-
Tgal
|
|
05 | 3.4115: Recover and reuse cooling water | $17,077 | $10,098 | - | - | - |
$17,077
-
Tgal
|
|
TOTAL RECOMMENDED | $59,447 | $81,813 |
$17,280
528,429
kWh
|
$11,278
-
kW-mo/yr
|
$10,071
-
MMBtu
|
$20,818
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs