Assessment Year | 2014 |
---|---|
Principal Product | Lumber |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $5 M to 10M |
# of Employees | 43 |
Plant Area |
34,670
ft2
|
Annual Production | 14,000
thousand feet
|
Production Hrs. Annual | 2,142
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $188,073 | 1,881,393 |
kWh
|
$0.100 |
Electricity Fees | $13,037 | - |
|
- |
Wood | $95,721 | 83,966 |
MMBtu
|
$1.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,933 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,736 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings |
---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $1,874 | $2,437 | - |
$1,874
-
MMBtu
|
|
02 | 2.2121: Increase amount of condensate returned | $1,954 | $2,500 | - |
$1,954
-
MMBtu
|
|
03 | 2.1113: Reduce combustion air flow to optimum | $2,753 | $7,500 | - |
$2,753
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,029 | $6,195 |
$5,029
47,354
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,600 | $4,720 |
$3,600
33,914
kWh
|
- | |
06 | 2.7261: Install timers and/or thermostats | $1,635 | $360 |
$1,635
15,409
kWh
|
- | |
07 | 2.7134: Use photocell controls | $88 | $192 |
$88
830
kWh
|
- | |
TOTAL RECOMMENDED | $16,933 | $23,904 |
$10,352
97,507
kWh
|
$6,581
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,736 | $16,195 |
$5,029
47,354
kWh
|
$4,707
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs