Assessment Year | 2010 |
---|---|
Principal Product | Large Machined Metal Parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
120,000
ft2
|
Annual Production | 25
pieces
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $201,414 | 2,484,300 |
kWh
|
$0.081 |
Natural Gas | $53,397 | 3,654 |
MMBtu
|
$14.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,495 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,124 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,876 | $3,000 |
$9,876
135,844
kWh
|
|
02 | 2.6231: Utilize controls to operate equipment only when needed | $7,848 | $80 |
$7,848
107,955
kWh
|
|
03 | 2.6218: Turn off equipment when not in use | $4,400 | $2,080 |
$4,400
60,519
kWh
|
|
04 | 2.7141: Lower light fixtures in high ceiling areas | $11,362 | $71,030 |
$11,362
156,290
kWh
|
|
05 | 2.7134: Use photocell controls | $8,910 | $1,742 |
$8,910
122,564
kWh
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $6,885 | $250 |
$6,885
94,708
kWh
|
|
07 | 2.7261: Install timers and/or thermostats | $3,185 | $1,020 |
$3,185
43,813
kWh
|
|
08 | 2.4323: Use optimum size and capacity equipment | $3,029 | $12,535 |
$3,029
41,660
kWh
|
|
TOTAL RECOMMENDED | $55,495 | $91,737 |
$55,495
763,353
kWh
|
||
TOTAL IMPLEMENTED | $22,124 | $5,160 |
$22,124
304,318
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs