Assessment Year 2009
Principal Product Medium and High Voltage Cable
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3355: Aluminum Rolling and Drawing, Not Elsewhere Classified
Sales Range less than $500
k
# of Employees 215
Plant Area 339,000
ft2
Annual Production 55,000,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,451,368 23,697,890
kWh
Natural Gas $75,219 4,945
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $149,449 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $142,368

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $16,663 - $16,663
266,865
kWh
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $14,535 $3,000 $14,535
232,784
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $88,243 $220,339 $88,243
1,413,240
kWh
-
04 2.7122: Disconnect ballasts $2,487 $162 $2,487
39,836
kWh
-
05 2.7261: Install timers and/or thermostats $4,594 $680 $4,594
73,581
kWh
-
06 2.2437: Recover waste heat from equipment $19,240 $2,900 - $19,240
-
MMBtu
07 2.2212: Use minimum safe oven ventilation $3,687 $4,300 - $3,687
-
MMBtu
TOTAL RECOMMENDED $149,449 $231,381 $126,522
2,026,306
kWh
$22,927
-
MMBtu
TOTAL IMPLEMENTED $142,368 $230,539 $119,441
1,912,889
kWh
$22,927
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs