| Assessment Year | 2007 |
|---|---|
| Principal Product | Trash Compactors |
| NAICS | 332420: Metal Tank (Heavy Gauge) Manufacturing |
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $50 M to 100M |
| # of Employees | 308 |
| Plant Area |
159,600
ft2
|
| Annual Production | 4,212
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $336,700 | 4,371,053 |
kWh
|
$0.077 |
| Electricity Demand | $5,754 | 16,786 |
kW-mo/yr
|
$0.34 |
| Natural Gas | $138,197 | 11,262 |
MMBtu
|
$12.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,056 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,314 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,084 | $70,481 |
$14,083
182,827
kWh
|
$1
-
kW-mo/yr
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,004 | $14,292 |
$2,003
26,008
kWh
|
$1
-
kW-mo/yr
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $742 | - |
$742
9,639
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $426 | $590 |
$426
9,953
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,616 | $700 |
$1,616
20,982
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $96 | $528 |
$96
1,219
kWh
|
- | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $933 | - |
$933
12,118
kWh
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $155 | $320 |
$155
2,016
kWh
|
- | |
| TOTAL RECOMMENDED | $20,056 | $86,911 |
$20,054
264,762
kWh
|
$2
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $19,314 | $86,911 |
$19,312
255,123
kWh
|
$2
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs