Assessment Year | 2023 |
---|---|
Principal Product | Residential Water Heaters |
NAICS | 335228: Other Major Household Appliance Manufacturing |
SIC | 3639: Household Appliances, Not Elsewhere Classified |
Sales Range | greater than $500 M |
# of Employees | 1,200 |
Plant Area |
1,300,000
ft2
|
Annual Production | 1,600,000
units
|
Production Hrs. Annual | 4,590
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,240,435 | 30,465,757 |
kWh
|
$0.041 | |
Electricity Demand | $880,427 | 63,772 |
kW-mo/yr
|
$13.81 | |
Electricity Fees | $199,567 | - |
|
- | |
Natural Gas | $1,468,184 | 317,808 |
MMBtu
|
$4.62 | |
Waste Disposal Costs | |||||
Water Usage | $337,243 | 40,093 |
Tgal
|
$8.41 | |
Water Disposal | $118,043 | 14,246 |
Tgal
|
$8.29 | |
TOTAL YEARLY COSTS | $4,243,899 | ||||
RECOMMENDED SAVINGS* | $236,367 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.4151: Minimize water usage | $54,343 | $42,000 | - | - | - |
$54,343
-
Tgal
|
- | |
02 | 2.9114: Use solar heat to make electricty | $32,300 | $196,225 |
$32,300
793,567
kWh
|
- | - | - | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $26,893 | $45,000 |
$18,361
451,140
kWh
|
$8,532
-
kW-mo/yr
|
- | - | - | |
04 | 2.2511: Insulate bare equipment | $26,094 | $85,000 | - | - |
$26,094
-
MMBtu
|
- | - | |
05 | 2.2522: Isolate hot or cold equipment | $25,424 | $60,000 | - | - |
$25,424
-
MMBtu
|
- | - | |
06 | 4.212: Adopt in-house material generation | $20,290 | $61,440 |
$(-710.0)
(-17,456)
kWh
|
- | - | - | $21,000 | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,545 | $31,800 |
$12,545
308,219
kWh
|
- | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $9,325 | $22,800 |
$9,325
229,119
kWh
|
- | - | - | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,862 | $9,000 |
$4,521
111,078
kWh
|
$3,341
-
kW-mo/yr
|
- | - | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,044 | $13,500 |
$7,044
173,066
kWh
|
- | - | - | - | |
11 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,983 | $9,000 |
$5,983
146,995
kWh
|
- | - | - | - | |
12 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,575 | $2,010 |
$4,575
112,406
kWh
|
- | - | - | - | |
13 | 2.2437: Recover waste heat from equipment | $3,689 | $9,000 | - | - |
$3,689
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $236,367 | $586,775 |
$93,944
2,308,134
kWh
|
$11,873
-
kW-mo/yr
|
$55,207
-
MMBtu
|
$54,343
-
Tgal
|
$21,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs