| Assessment Year | 2017 |
|---|---|
| Principal Product | Cotton and Poly Cotton Book/ Passport Coverings |
| NAICS | 313320: Fabric Coating Mills |
| SIC | 2295: Coated Fabrics, Not Rubberized |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
294,315
ft2
|
| Annual Production | 15,000
thousand feet
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $308,177 | 4,637,800 |
kWh
|
$0.066 |
| Electricity Demand | $178,661 | 16,076 |
kW-mo/yr
|
$11.11 |
| Natural Gas | $429,304 | 59,487 |
MMBtu
|
$7.22 |
| TOTAL YEARLY COSTS | $916,142 | |||
| RECOMMENDED SAVINGS* | $119,326 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.4133: Clean fouling from water lines regularly | $91,197 | $8,500 | - | - | - | $91,197 | |
| 02 | 2.2113: Repair or replace steam traps | $14,682 | $4,830 | - | - |
$14,682
-
MMBtu
|
- | |
| 03 | 2.3212: Optimize plant power factor | $5,729 | $8,000 | - |
$5,729
-
kW-mo/yr
|
- | - | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $3,003 | $25 |
$749
11,267
kWh
|
$2,254
-
kW-mo/yr
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,715 | $11,600 |
$2,354
35,400
kWh
|
$2,361
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $119,326 | $32,955 |
$3,103
46,667
kWh
|
$10,344
-
kW-mo/yr
|
$14,682
-
MMBtu
|
$91,197 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs