Assessment Year | 2017 |
---|---|
Principal Product | Water |
NAICS | 237130: Power and Communication Line and Related Structures Construction |
SIC | 1623: Water, Sewer, Pipeline, and Communications and Power Line Construction |
Sales Range | $1 M to 5M |
# of Employees | 7 |
Plant Area |
225,000
ft2
|
Annual Production | 2,100,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $346,727 | 5,420,320 |
kWh
|
$0.064 |
Electricity Demand | $173,914 | 13,756 |
kW-mo/yr
|
$12.64 |
TOTAL YEARLY COSTS | $520,641 | |||
RECOMMENDED SAVINGS* | $122,496 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,844 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $50,844 | $10,000 |
$23,549
367,957
kWh
|
$27,295
-
kW-mo/yr
|
|
02 | 2.4322: Use or replace with energy efficient substitutes | $39,874 | $199,100 |
$7,164
111,933
kWh
|
$32,710
-
kW-mo/yr
|
|
03 | 2.4157: Establish a predictive maintenance program | $31,778 | $50,000 |
$20,733
323,960
kWh
|
$11,045
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $122,496 | $259,100 |
$51,446
803,850
kWh
|
$71,050
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $50,844 | $10,000 |
$23,549
367,957
kWh
|
$27,295
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs