Assessment Year | 2013 |
---|---|
Principal Product | RV Ranges and Water Heaters |
NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | $50 M to 100M |
# of Employees | 140 |
Plant Area |
65,000
ft2
|
Annual Production | 425,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,682 | 1,198,560 |
kWh
|
$0.067 |
Electricity Demand | $67,268 | 5,842 |
kW-mo/yr
|
$11.51 |
Natural Gas | $55,319 | 6,053 |
MMBtu
|
$9.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,293 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,769 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1133: Adjust burners for efficient operation | $3,611 | $50 | - | - | - |
$3,611
-
MMBtu
|
|
02 | 2.3212: Optimize plant power factor | $17,524 | $25,600 | - |
$17,524
-
kW-mo/yr
|
- | - | |
03 | 2.4224: Upgrade controls on compressors | $7,651 | $25 |
$3,842
57,346
kWh
|
$3,809
-
kW-mo/yr
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,206 | $63 |
$605
9,036
kWh
|
$601
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,030 | $20,000 |
$1,132
16,900
kWh
|
$898
-
kW-mo/yr
|
- | - | |
06 | 4.812: Apply for investment incentives | $2,271 | - | - | - | $2,271 | - | |
TOTAL RECOMMENDED | $34,293 | $45,738 |
$5,579
83,282
kWh
|
$22,832
-
kW-mo/yr
|
$2,271 |
$3,611
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,769 | $20,138 |
$5,579
83,282
kWh
|
$5,308
-
kW-mo/yr
|
$2,271 |
$3,611
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs