Assessment Year | 2013 |
---|---|
Principal Product | Hardwood Lumber |
NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
500,000
ft2
|
Annual Production | 24,000
thousand feet
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $276,489 | 4,078,440 |
kWh
|
$0.068 |
Electricity Demand | $114,934 | 11,151 |
kW-mo/yr
|
$10.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,055 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4113: Install motor voltage controller on lightly loaded motors | $382 | $50 |
$320
4,575
kWh
|
$62
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $13,653 | $5,720 |
$13,653
195,043
kWh
|
- | |
03 | 2.4157: Establish a predictive maintenance program | $8,455 | $13,594 |
$6,848
97,834
kWh
|
$1,607
-
kW-mo/yr
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,565 | $16,000 |
$6,565
93,792
kWh
|
- | |
TOTAL RECOMMENDED | $29,055 | $35,364 |
$27,386
391,244
kWh
|
$1,669
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $22,108 | $19,314 |
$20,501
292,877
kWh
|
$1,607
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs