ITAC Assessment: TT0098
ITAC logo
ITAC Assessment: TT0098
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2012
Principal Product Motor Vehicle Parts And Accessories
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 100,000
ft2
Annual Production 0
units
Production Hrs. Annual 1,500
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,648 3,066,600
kWh
Electricity Demand $71,437 6,815
kW-mo/yr
Natural Gas $10,013 1,182
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,368 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,656

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7226: Use computer programs to optimize hvac performance $1,053 $1,116 $873
10,040
kWh
- $179
-
MMBtu
02 2.7447: Install vinyl strip / high speed / air curtain doors $1,222 $2,320 $1,222
19,270
kWh
- -
03 2.3512: De-energize excess transformer capacity $1,898 $5,525 $1,898
30,613
kWh
- -
04 2.9111: Use solar heat to heat make-up air $5,814 $43,695 - - $5,814
-
MMBtu
05 2.2135: Repair and eliminate steam leaks $7,381 $980 $3,721
41,804
kWh
$3,660
-
kW-mo/yr
-
TOTAL RECOMMENDED $17,368 $53,636 $7,715
101,728
kWh
$3,660
-
kW-mo/yr
$5,993
-
MMBtu
TOTAL IMPLEMENTED $9,656 $4,416 $5,816
71,114
kWh
$3,660
-
kW-mo/yr
$179
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs