| Assessment Year | 2010 |
|---|---|
| Principal Product | Roasted Nuts |
| NAICS | 311911: Roasted Nuts and Peanut Butter Manufacturing |
| SIC | 2068: Salted and Roasted Nuts and Seeds |
| Sales Range | less than $500 k |
| # of Employees | 330 |
| Plant Area |
158,000
ft2
|
| Annual Production | 54,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $438,153 | 7,494,840 |
kWh
|
$0.058 |
| Electricity Demand | $154,320 | 13,376 |
kW-mo/yr
|
$11.54 |
| Natural Gas | $106,464 | 16,808 |
MMBtu
|
$6.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $66,340 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,400 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Gaseous Waste Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.1161: Eliminate/reduce an operation | $55,600 | - | - | - |
$55,600
-
lb
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,700 | $10,500 |
$1,800
40,800
kWh
|
$2,900
-
kW-mo/yr
|
- | |
| 03 | 2.4131: Size electric motors for peak operating efficiency | $3,000 | $10 |
$1,800
40,560
kWh
|
$1,200
-
kW-mo/yr
|
- | |
| 04 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $2,700 | $1,000 | - | - |
$2,700
-
lb
|
|
| 05 | 2.7134: Use photocell controls | $340 | $520 |
$340
7,500
kWh
|
- | - | |
| TOTAL RECOMMENDED | $66,340 | $12,030 |
$3,940
88,860
kWh
|
$4,100
-
kW-mo/yr
|
$58,300
-
lb
|
||
| TOTAL IMPLEMENTED | $10,400 | $11,510 |
$3,600
81,360
kWh
|
$4,100
-
kW-mo/yr
|
$2,700
-
lb
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs