| Assessment Year | 2010 |
|---|---|
| Principal Product | EPS Loose fill |
| NAICS | 326150: Urethane and Other Foam Product (except Polystyrene) Manufacturing |
| SIC | 3085: Plastics Bottles |
| Sales Range | $10 M to 50M |
| # of Employees | 126 |
| Plant Area |
266,940
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $807,551 | 10,550,400 |
kWh
|
$0.077 |
| Natural Gas | $9,786 | 1,215 |
MMBtu
|
$8.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $65,019 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,756 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7241: Install outside air damper / economizer on hvac unit | $5,280 | $9,600 |
$5,280
104,519
kWh
|
- | |
| 02 | 2.2113: Repair or replace steam traps | $9,803 | $4,000 |
$9,803
194,036
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,257 | $50 |
$1,257
24,889
kWh
|
- | |
| 04 | 2.4151: Develop a repair/replace policy | $16,200 | $18,200 |
$16,200
321,000
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,756 | $173,505 |
$16,614
325,775
kWh
|
$5,142 | |
| 06 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $10,723 | - |
$10,723
204,449
kWh
|
- | |
| TOTAL RECOMMENDED | $65,019 | $205,355 |
$59,877
1,174,668
kWh
|
$5,142 | ||
| TOTAL IMPLEMENTED | $21,756 | $173,505 |
$16,614
325,775
kWh
|
$5,142 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs