Assessment Year | 2010 |
---|---|
Principal Product | EPS Loose fill |
NAICS | 326150: Urethane and Other Foam Product (except Polystyrene) Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 126 |
Plant Area |
266,940
ft2
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $807,551 | 10,550,400 |
kWh
|
$0.077 |
Natural Gas | $9,786 | 1,215 |
MMBtu
|
$8.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,019 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,756 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $5,280 | $9,600 |
$5,280
104,519
kWh
|
- | |
02 | 2.2113: Repair or replace steam traps | $9,803 | $4,000 |
$9,803
194,036
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,257 | $50 |
$1,257
24,889
kWh
|
- | |
04 | 2.4151: Develop a repair/replace policy | $16,200 | $18,200 |
$16,200
321,000
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,756 | $173,505 |
$16,614
325,775
kWh
|
$5,142 | |
06 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $10,723 | - |
$10,723
204,449
kWh
|
- | |
TOTAL RECOMMENDED | $65,019 | $205,355 |
$59,877
1,174,668
kWh
|
$5,142 | ||
TOTAL IMPLEMENTED | $21,756 | $173,505 |
$16,614
325,775
kWh
|
$5,142 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs