Assessment Year | 2016 |
---|---|
Principal Product | Electronic Printed Circuits |
NAICS | 334412: Bare Printed Circuit Board Manufacturing |
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
93,000
ft2
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $172,872 | 2,903,040 |
kWh
|
$0.060 |
Electricity Demand | $87,844 | 6,906 |
kW-mo/yr
|
$12.72 |
Electricity Fees | $23,096 | - |
|
- |
TOTAL YEARLY COSTS | $283,812 | |||
RECOMMENDED SAVINGS* | $118,919 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $57,076 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $34,838 | $36,314 |
$22,016
366,941
kWh
|
$12,822
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,018 | $53,398 |
$9,112
151,865
kWh
|
$9,906
-
kW-mo/yr
|
|
03 | 2.7293: Install dry sprinkler system or other method to reduce heating requirements | $16,796 | $40,060 |
$13,005
216,757
kWh
|
$3,791
-
kW-mo/yr
|
|
04 | 2.7221: Lower temperature during the winter season and vice-versa | $15,528 | $40 |
$12,026
200,430
kWh
|
$3,502
-
kW-mo/yr
|
|
05 | 2.2437: Recover waste heat from equipment | $9,324 | $3,985 |
$4,465
74,411
kWh
|
$4,859
-
kW-mo/yr
|
|
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,991 | $8,588 |
$4,310
71,839
kWh
|
$4,681
-
kW-mo/yr
|
|
07 | 2.4239: Eliminate or reduce compressed air usage | $6,682 | $5,600 |
$3,171
52,846
kWh
|
$3,511
-
kW-mo/yr
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,220 | $1,660 |
$1,541
25,680
kWh
|
$1,679
-
kW-mo/yr
|
|
09 | 2.7134: Use photocell controls | $2,087 | $2,520 |
$2,087
34,782
kWh
|
- | |
10 | 2.7221: Lower temperature during the winter season and vice-versa | $1,219 | $40 |
$944
15,726
kWh
|
$275
-
kW-mo/yr
|
|
11 | 2.7111: Reduce illumination to minimum necessary levels | $664 | $760 |
$318
5,298
kWh
|
$346
-
kW-mo/yr
|
|
12 | 2.7135: Install occupancy sensors | $552 | $177 |
$552
9,208
kWh
|
- | |
TOTAL RECOMMENDED | $118,919 | $153,142 |
$73,547
1,225,783
kWh
|
$45,372
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $57,076 | $91,372 |
$32,669
544,486
kWh
|
$24,407
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs