Assessment Year 2009
Principal Product Photographic Chemicals
NAICS 325992: Photographic Film, Paper, Plate, and Chemical Manufacturing
SIC 2869: Industrial Organic Chemicals, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 111,553
ft2
Annual Production 1
units
Production Hrs. Annual 8,760
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $339,167 5,391,360
kWh
Electricity Fees $54,700 -
Natural Gas $554,957 45,043
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $201,094 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $118,916

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Energy Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $11,230 $10,800 $7,800
106,811
kWh
$1,780
-
kW-mo/yr
- - $1,650
02 2.2113: Repair or replace steam traps $78,500 $40,000 - - $78,500
-
MMBtu
- -
03 2.2449: Recover heat from exhausted steam, hot air or hot water $45,100 $15,000 - - - $45,100
-
MMBtu
-
04 2.2414: Use waste heat from hot flue gases to preheat $18,000 $36,000 - - $18,000
-
MMBtu
- -
05 2.2121: Increase amount of condensate returned $7,848 $8,000 - - $7,848
-
MMBtu
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,616 $2,500 $7,616
120,896
kWh
- - - -
07 2.4322: Use or replace with energy efficient substitutes $8,200 - - - - - $8,200
08 2.4226: Use / purchase optimum sized compressor $24,600 $27,800 $24,600
326,748
kWh
- - - -
TOTAL RECOMMENDED $201,094 $140,100 $40,016
554,455
kWh
$1,780
-
kW-mo/yr
$104,348
-
MMBtu
$45,100
-
MMBtu
$9,850
TOTAL IMPLEMENTED $118,916 $70,300 $32,216
447,644
kWh
- $78,500
-
MMBtu
- $8,200
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Energy Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs