Assessment Year | 2009 |
---|---|
Principal Product | Corrigated Containers |
NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 142 |
Plant Area |
225,000
ft2
|
Annual Production | 264,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,466 | 2,909,880 |
kWh
|
$0.085 |
Natural Gas | $15,651 | 1,361 |
MMBtu
|
$11.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,144 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,617 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $852 | $850 |
$852
9,470
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,178 | $480 |
$14,194
157,706
kWh
|
$3,984
-
kW-mo/yr
|
- | |
03 | 2.7134: Use photocell controls | $23,587 | $55,000 |
$23,587
262,080
kWh
|
- | - | |
04 | 2.1336: Install equipment to utilize waste fuel | $10,527 | $36,300 | - | - |
$10,527
-
MMBtu
|
|
TOTAL RECOMMENDED | $53,144 | $92,630 |
$38,633
429,256
kWh
|
$3,984
-
kW-mo/yr
|
$10,527
-
MMBtu
|
||
TOTAL IMPLEMENTED | $42,617 | $56,330 |
$38,633
429,256
kWh
|
$3,984
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs