Assessment Year | 2007 |
---|---|
Principal Product | Steering Gears |
NAICS | 336330: Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
230,525
ft2
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,023,195 | 41,014,800 |
kWh
|
$0.049 |
Natural Gas | $69,057 | 4,639 |
MMBtu
|
$14.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $239,315 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $225,415 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $541 | $360 |
$541
9,008
kWh
|
- | - | - | |
02 | 4.812: Apply for investment incentives | $21,551 | $110 | - | - | - | $21,551 | |
03 | 2.8113: Purchase gas directly from a contract gas supplier | $13,359 | $1,200 | - | - |
$13,359
-
MMBtu
|
- | |
04 | 2.3522: Increase electrical conductor size to reduce distribution losses | $44,581 | $51,000 |
$44,581
891,626
kWh
|
- | - | - | |
05 | 2.4156: Establish a preventative maintenance program | $159,283 | $2,912 | - | $159,283 | - | - | |
TOTAL RECOMMENDED | $239,315 | $55,582 |
$45,122
900,634
kWh
|
$159,283 |
$13,359
-
MMBtu
|
$21,551 | ||
TOTAL IMPLEMENTED | $225,415 | $54,022 |
$44,581
891,626
kWh
|
$159,283 | - | $21,551 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs