| Assessment Year | 2007 |
|---|---|
| Principal Product | Engineered Wood Products |
| NAICS | 321219: Reconstituted Wood Product Manufacturing |
| SIC | 2493: Reconstituted Wood Products |
| Sales Range | $100 M to 500M |
| # of Employees | 145 |
| Plant Area |
205,000
ft2
|
| Annual Production | 425,000
thousand feet
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,956,974 | 64,235,204 |
kWh
|
$0.046 |
| Electricity Demand | $931,433 | 70,638 |
kW-mo/yr
|
$13.19 |
| Natural Gas | $2,287,645 | 276,044 |
MMBtu
|
$8.29 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $158,070 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4227: Use compressor air filters | $25,442 | $42,225 |
$25,442
584,885
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,000 | $10,900 |
$12,000
458,015
kWh
|
- | |
| 03 | 2.4227: Use compressor air filters | $20,463 | $2,000 |
$20,463
152,184
kWh
|
- | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $38,638 | $57,958 |
$38,638
914,000
kWh
|
- | |
| 05 | 2.2113: Repair or replace steam traps | $13,341 | $4,000 |
$13,341
474,760
kWh
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,294 | $480 |
$850
30,537
kWh
|
$444
-
kW-mo/yr
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $46,892 | $73,290 |
$27,811
636,388
kWh
|
$19,081
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $158,070 | $190,853 |
$138,545
3,250,769
kWh
|
$19,525
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs