| Assessment Year | 2007 |
|---|---|
| Principal Product | Electric Heating Elements |
| NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
| SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 350 |
| Plant Area |
203,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 7,100
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $197,514 | 4,706,000 |
kWh
|
$0.042 |
| Electricity Demand | $114,028 | 10,228 |
kW-mo/yr
|
$11.15 |
| Natural Gas | $3,525 | 208 |
MMBtu
|
$16.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $144,007 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $46,248 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $13,371 | - |
$13,371
183,165
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $20,500 | $8,381 |
$20,500
114,808
kWh
|
- | |
| 03 | 2.3212: Optimize plant power factor | $3,500 | $8,000 | - | $3,500 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $612 | $1,318 |
$612
8,491
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,680 | $16,138 |
$5,680
54,184
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $50,171 | $150,176 |
$50,171
570,145
kWh
|
- | |
| 07 | 2.2437: Recover waste heat from equipment | $17,296 | $3,500 |
$17,296
236,925
kWh
|
- | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $9,553 | $14,000 |
$9,553
130,867
kWh
|
- | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $23,324 | $1,400 |
$23,324
319,500
kWh
|
- | |
| TOTAL RECOMMENDED | $144,007 | $202,913 |
$140,507
1,618,085
kWh
|
$3,500 | ||
| TOTAL IMPLEMENTED | $46,248 | $15,400 |
$46,248
633,532
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs