| Assessment Year | 1986 |
|---|---|
| Principal Product | POLYETHYLENE FOAM PADDIN |
| NAICS |
n/a
|
| SIC | 3086: Plastics Foam Products |
| Sales Range | n/a |
| # of Employees | 105 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $469,927 | 7,244,432 |
kWh
|
$0.065 |
| Natural Gas | $241,704 | 48,997 |
MMBtu
|
$4.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,196 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $13,881 | $2,730 | - |
$13,881
-
MMBtu
|
|
| 02 | 2.2515: Use optimum thickness insulation | $1,345 | $2,730 |
$1,345
20,809
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,996 | $178 |
$1,996
30,774
kWh
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $1,601 | - |
$1,601
24,619
kWh
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,451 | $1,000 |
$1,451
22,274
kWh
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $922 | $1,300 | - |
$922
-
MMBtu
|
|
| TOTAL RECOMMENDED | $21,196 | $7,938 |
$6,393
98,476
kWh
|
$14,803
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs