| Assessment Year | 2018 |
|---|---|
| Principal Product | Wastewater Treatment |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
609,840
ft2
|
| Annual Production | 9,100,000
Tgal
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,436,352 | 15,246,010 |
kWh
|
$0.094 | |
| Natural Gas | $494,516 | 108,488 |
MMBtu
|
$4.56 | |
| Waste Disposal Costs | |||||
| Water Usage | $113,740 | 609,840 |
Tgal
|
$0.19 | |
| TOTAL YEARLY COSTS | $2,044,608 | ||||
| RECOMMENDED SAVINGS* | $325,487 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6125: Keep equipment clean | $25,586 | $12,000 | - |
$25,586
-
MMBtu
|
|
| 02 | 2.1336: Install equipment to utilize waste fuel | $97,475 | $50,000 | - |
$97,475
-
MMBtu
|
|
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $104,092 | $125,000 |
$104,092
1,107,360
kWh
|
- | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $30,220 | $126,000 |
$30,220
321,492
kWh
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,729 | $13,500 |
$18,729
199,249
kWh
|
- | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,292 | $8,675 |
$18,292
194,597
kWh
|
- | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $8,160 | $30,000 |
$8,160
86,812
kWh
|
- | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $22,933 | $40,500 |
$22,933
243,972
kWh
|
- | |
| TOTAL RECOMMENDED | $325,487 | $405,675 |
$202,426
2,153,482
kWh
|
$123,061
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs