Assessment Year | 1985 |
---|---|
Principal Product | ELECTRICAL ENCLOSURES |
NAICS |
n/a
|
SIC | 3643: Current-Carrying Wiring Devices |
Sales Range | $5 M to 10M |
# of Employees | 78 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $145,676 | 1,531,067 |
kWh
|
$0.095 |
Natural Gas | $39,991 | 7,632 |
MMBtu
|
$5.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,344 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,285 | $50 |
$1,285
13,482
kWh
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,906 | - |
$1,906
-
kWh
|
- | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,153 | $1,000 | - |
$1,153
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,344 | $1,050 |
$3,191
13,482
kWh
|
$1,153
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs