| Assessment Year | 2023 |
|---|---|
| Principal Product | High temperature alloy bonded and welded exhaust structures & metal honeycomb core |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 97 |
| Plant Area |
140,000
ft2
|
| Annual Production | 450
units
|
| Production Hrs. Annual | 7,224
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $379,448 | 8,782,588 |
kWh
|
$0.043 | |
| Electricity Demand | $194,324 | 24,924 |
kW-mo/yr
|
$7.80 | |
| Electricity Fees | $34,441 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $31,084 | 3,283 |
Tgal
|
$9.47 | |
| Water Disposal | $25,109 | 3,127 |
Tgal
|
$8.03 | |
| TOTAL YEARLY COSTS | $664,405 | ||||
| RECOMMENDED SAVINGS* | $69,147 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $33,031 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $33,031 | $5,000 | - | - | $33,031 | |
| 02 | 2.3191: Use demand controller or load shedder | $34,391 | $20,500 | - |
$34,391
-
kW-mo/yr
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,725 | $389 |
$1,327
30,723
kWh
|
$398
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $69,147 | $25,889 |
$1,327
30,723
kWh
|
$34,789
-
kW-mo/yr
|
$33,031 | ||
| TOTAL IMPLEMENTED | $33,031 | $5,000 | - | - | $33,031 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs