Assessment Year | 2023 |
---|---|
Principal Product | Injection Molding Plastics |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 473 |
Plant Area |
350,000
ft2
|
Annual Production | 1,950,000
pieces
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $835,483 | 11,854,800 |
kWh
|
$0.070 |
Electricity Demand | $160,855 | 21,935 |
kW-mo/yr
|
$7.33 |
Electricity Fees | $43,012 | - |
|
- |
TOTAL YEARLY COSTS | $1,039,350 | |||
RECOMMENDED SAVINGS* | $290,138 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $73,932 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $5,441 | $10,000 |
$4,763
67,577
kWh
|
$679
-
kW-mo/yr
|
|
02 | 2.4133: Use most efficient type of electric motors | $62,708 | $9,722 |
$54,885
778,772
kWh
|
$7,823
-
kW-mo/yr
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $7,119 | $1,204 |
$6,214
88,166
kWh
|
$906
-
kW-mo/yr
|
|
04 | 2.3212: Optimize plant power factor | $4,104 | $9,500 | - |
$4,104
-
kW-mo/yr
|
|
05 | 2.9114: Use solar heat to make electricty | $210,765 | $1,396,349 |
$183,962
2,610,265
kWh
|
$26,803
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $290,138 | $1,426,775 |
$249,823
3,544,779
kWh
|
$40,315
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $73,932 | $20,426 |
$61,099
866,937
kWh
|
$12,833
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs