Assessment Year | 1997 |
---|---|
Principal Product | Hydraulic pressing systems |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 87 |
Plant Area |
30,000
ft2
|
Annual Production | 10
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $27,697 | 586,460 |
kWh
|
$0.047 |
Electricity Demand | $14,500 | 3,196 |
kW-mo/yr
|
$4.54 |
Electricity Fees | $5,208 | - |
|
- |
Natural Gas | $21,529 | 3,198 |
MMBtu
|
$6.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,230 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,210 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.122: Develop standard procedures to improve internal yields | $60,000 | $19,780 | - | - | - | - | - | $(-100,000.0) | - | $160,000 | |
02 | 3.2124: Convert to air assisted / airless paint guns | $7,980 | $13,100 | - | - | - | - | - | - | $7,980 | - | |
03 | 2.7231: Use radiant heater for spot heating | $6,870 | $10,000 | - |
$6,870
-
MMBtu
|
- | - | - | - | - | - | |
04 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $4,930 | - | - | - | - |
$7,800
-
lb
|
$(-1,950.0) | - | $(-920.0) | - | |
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $1,400 | $3,700 | - | - |
$1,400
-
Tgal
|
- | - | - | - | - | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,140 | $640 |
$1,140
24,326
kWh
|
- | - | - | - | - | - | - | |
07 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $900 | - | - | - | - |
$900
-
lb
|
- | - | - | - | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $870 | $2,500 | - |
$870
-
MMBtu
|
- | - | - | - | - | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $140 | - |
$140
2,931
kWh
|
- | - | - | - | - | - | - | |
TOTAL RECOMMENDED | $84,230 | $49,720 |
$1,280
27,257
kWh
|
$7,740
-
MMBtu
|
$1,400
-
Tgal
|
$8,700
-
lb
|
$(-1,950.0) | $(-100,000.0) | $7,060 | $160,000 | ||
TOTAL IMPLEMENTED | $66,210 | $20,420 |
$1,280
27,257
kWh
|
- | - |
$7,800
-
lb
|
$(-1,950.0) | $(-100,000.0) | $(-920.0) | $160,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs